EN
DT-R24L4D
DT-R17L4D
MULTI FORMAT LCD MONITOR INSTRUCTIONS
The illustration of the monitor is of DT-R24L4D.
CAUTION:
To reduce the risk of electric shock. Do
not remove cover (or back). No user
serviceable parts inside. Refer servicing
to qualified service personnel.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
The lightning flash with arrowhead
symbol, within an equilateral triangle is
intended to alert the user to the presence
of uninsulated “dangerous voltage”
within the product’s enclosure that may
be of sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.
CAUTION
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - DT-R17L4D

ENDT-R24L4DDT-R17L4DMULTI FORMAT LCD MONITOR INSTRUCTIONSThe illustration of the monitor is of DT-R24L4D.CAUTION: To reduce the risk of electric shoc

Seite 2 - Table of Contents

10Front panel1 Speakers (stereo)The speakers emit the same audio signal emitted from the AUDIO ASSIGN (DT-R24L4D) / AUDIO (DT-R17L4D) (MONITOR OUT) t

Seite 3 - Safety Precautions

11ENSelect audio channels emitted from the speakers (L/R) and the AUDIO ASSIGN (DT-R24L4D) / AUDIO (DT-R17L4D) (MONITOR OUT) (OUT1(L)/OUT2(R)) termina

Seite 4 - Safety Precautions (cont.)

12The operation procedure1 Display the menu.To display the MAIN MENUPress MENU button.To display the SET-UP MENUPress button while holding button.

Seite 5

13ENMAIN MENUPICTURE FUNCTIONSetting for the picture qualityItem To do Setting valueAPERTURE*1Activates/deactivates the function at the level set in “

Seite 6 - Installation

14Menu Confi guration (cont.)MARKER*1*2Settings for marker functions2/2Item To do Setting valueR-AREA MARKER*3Activate/deactivate the area marker and s

Seite 7 - Caution

15ENSYNC FUNCTIONSettings for the synchronization with signalsItem To do Setting valueNO SYNC ACTION Select the screen status when no signal is coming

Seite 8 - Connections

16Menu Confi guration (cont.)SIZE/POSI. ADJ.Adjusts the size and position of the picture.Item To do Setting valueH SIZE*1Adjust the horizontal picture

Seite 9

17ENINFORMATIONSettings for the information display of the monitorItem To do Setting valuePOSITIONSelect the position to show the information display

Seite 10 - Daily Operations

18External ControlAbout the external controlThis monitor has three external control terminals.MAKE/TRIGGER terminal (RJ-45): The following external co

Seite 11 - On the signal format

19EN<Functions controlled by the MAKE/TRIGGER system>Display Functions to be controlled Opening Short-circuitingTALLY SEL Selects the color of t

Seite 12 - Menu Confi guration

2Table of ContentsSafety Precautions 3IMPORTANT SAFEGUARDS ... 3Caution f

Seite 13 - MAIN MENU

20External Control (cont.)Using the serial communicationYou can control the monitor from a personal computer etc. via the RS-485 or RS-232C terminal.C

Seite 14 - Menu Confi guration (cont.)

21EN<Basic command list>No. Commands Functions Data1 !*1B C N 1 Cr Starts communication (connection) No data2 !*1B C N 0 Cr Terminates communica

Seite 15 - SET-UP MENU

22TroubleshootingSolutions to common problems related to the monitor are described here. If none of the solutions presented here solve the problem, un

Seite 16

23ENSelf-check programThis monitor has a self-check function, which allows it to detect malfunctions and alert you. This makes troubleshooting easier.

Seite 17

24Specifi cationsGeneralModel name DT-R24L4D DT-R17L4DType Multi format LCD monitorScreen size Type 24 wide format Type 17 wide formatAspect ratio 16:1

Seite 18 - External Control

25ENDimensionsUnit: mm (inch)DT-R24L4D<Front view> <Side view> <Rear view>564 (22 1/4)300 (11 7/8)408 (16 1/8)413.1 (16 3/8)99 (4)5

Seite 19

26Available signalsThe following signals are available for this monitor.Video signalsNo. Signal nameSignal format shown in the status display (☞ page

Seite 20 - External Control (cont.)

27ENComputer signals (preset)DVI-D (HDCP) terminalsNo. Signal nameResolution FrequencyScan systemHorizontal Vertical Horizontal (kHz) Vertical (Hz)1 V

Seite 22 - Troubleshooting

3ENSafety PrecautionsWARNING: TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. NO OBJECTS FILLED WITH LIQUI

Seite 23 - Self-check program

4Safety Precautions (cont.)Slots and openings in the cabinet are provided for ventilation. These ensure reliable operation of the product and protect

Seite 24 - Specifi cations

5ENEuropean Union onlyDear Customer,This apparatus is in conformance with the valid European directives and standards regarding electromagnetic compat

Seite 25 - Dimensions

6InstallationCAUTIONDo not rest your arm on the monitor or lean against the monitor.Do not touch the LCD panel when installing the monitor.Be sure to

Seite 26 - Specifi cations (cont.)

7ENTo install the monitor on a wallYou can install the monitor on a wall by changing how the stand bottom plate is attached.Installation Only for Auth

Seite 27

81 POWER switchTurns AC power on or off.You need to press button (☞ t on page 10) to use the monitor after turning on the POWER switch.2 AC IN term

Seite 28

9EN6 For DT-R24L4D: AUDIO ASSIGN (MONITOR OUT) terminals (pin jack) / For DT-R17L4D: AUDIO (MONITOR OUT) terminals (pin jack)Output terminals for the